Power Monitoring Sensors - Enviromon https://enviromon.net/product-category/sensors/power-sensors/ Fri, 26 Apr 2024 18:08:57 +0000 en-CA hourly 1 https://wordpress.org/?v=6.5.2 https://enviromon.net/wp-content/uploads/2023/12/cropped-cropped-enviromon-favicon-1-32x32.png Power Monitoring Sensors - Enviromon https://enviromon.net/product-category/sensors/power-sensors/ 32 32 SP-WT External Battery Pack https://enviromon.net/product/sp-wt-external-battery-pack/ Tue, 02 Jan 2024 07:23:54 +0000 https://enviromon.net/?post_type=product&p=1292 Battery Monitoring 0-50A CT https://enviromon.net/product/battery-monitoring-0-50a-ct/ Tue, 02 Jan 2024 07:23:53 +0000 https://enviromon.net/?post_type=product&p=1271 Inline power Meter 16A – 25cm power in / out cable with bare ends https://enviromon.net/product/inline-power-meter-16a-25cm-power-in-out-cable-with-bare-ends/ Tue, 02 Jan 2024 07:23:53 +0000 https://enviromon.net/?post_type=product&p=1273 100A 100V 60Hz 1ph meter (four wire) https://enviromon.net/product/100a-100v-60hz-1ph-meter-four-wire/ Tue, 02 Jan 2024 07:23:53 +0000 https://enviromon.net/?post_type=product&p=1277

Power Monitoring Sensor

Remotely monitor power, eliminating the need for manual power audits as well as providing immediate alerts to potential problems. The Power Monitoring Sensor is compatible with securityProbe and sensorProbe+ (SP2+, SPX+) base units, connecting to the Modbus port of those devices. Product Codes :-
PMS220HC3P (230/400V 50Hz 3ph)
PMS230HCS (230V 50hz 1ph)
PMS110HCS (100V 60Hz 1ph)

PMS230-CT50 (230/400V 50Hz CT meter)
PMS120-CT50 (120/208V 60Hz CT meter)
PMS277-CT60 (277/480V 60Hz CT meter)

]]>
Contactless Current Meter https://enviromon.net/product/contactless-current-meter/ Tue, 02 Jan 2024 06:34:24 +0000 https://enviromon.net/?post_type=product&p=1223 Contactless Current Meter

Non-invasive monitoring of multi core power cables up to 32 Amps.

Typical current transformers require access to a single live wire. The Contactless Current Meter (CCM) does not need any splitting of cables, needs no electrician to install and is completely non invasive. With an accuracy of +/-5% (on factory calibrated cable) and +/- 10% on in field calibrated cables, the CCM gives sufficient accuracy to check for sufficient power overhead in your data center for capacity planning. It can also warn when approaching the tripping point of your breakers, and be utilized for PuE calculations.

 

Measuring Specifications  
Status Indication LED indication for power
LED array for calibration
Inputs Magnetic field sensing of current in multicore cable
Accuracy +/-5% when factory calibrated on cable of same type
+/-10% on non-factory calibrated cable
Components Manufactured using highly integrated, low power surface mount technology to ensure long term reliability.
Operating Environment Temperature: Min. -35°C Max. 80°C
Humidity: Min. 20% – Max. 80% (Non-condensing)
Interface  
Communications Cable: RJ-45 jack to sensor using UTP Cat 5e cable
Power Source Powered by the controller unit. No additional power needed
Power Consumption: Typical 7.25mWatt, 1.45mA
Maximum Cable Length: 50ft using standard CAT5/6 UTP cable
Dimensions: 49(W) x 45(H) x 51(D) mm
Mounting Cable mounted
Sensor Count 1
]]>
Dry Contact Sensor – Isolated https://enviromon.net/product/dry-contact-sensor-isolated/ Tue, 02 Jan 2024 06:33:41 +0000 https://enviromon.net/?post_type=product&p=1193 Dry Contact Sensor – Isolated

]]>
3rd Party Modbus / PMS (per device) https://enviromon.net/product/3rd-party-modbus-pms-per-device/ Tue, 02 Jan 2024 06:33:17 +0000 https://enviromon.net/?post_type=product&p=1184 InLine Power Meter https://enviromon.net/product/inline-power-meter/ Tue, 02 Jan 2024 06:33:16 +0000 https://enviromon.net/?post_type=product&p=1176

The power meter goes between the electrical source and the power strip, or individual appliance, monitoring the voltage (V), current (A) and Kilowat Hours (kWh) being consumed with billable grade accuracy. Remotely switch devices on and off with optional relay. Relays are Bi-Stable Latched relay, which retains it’s state regardless of whether it is receiving power or not.

Inline Power Meter is essential for:

  • Checking how close you are to tripping your circuit breaker
  • Ensure sufficient power overhead before adding new equipment to a circuit
  • Billing individual clients in co-located services
  • Monitoring up to 16 In-Line Power Meters from a single sensorProbe+

Advantages

Removing the controller from your power strip allows you to use a low cost basic power strip. This gives several advantages, in addition to the cost savings.

  • A single IP address to monitor multiple cabinets.
  • Hot swappable controller, no downtime to cabinets if servicing is needed
  • More space for outlets on your power strip as the controller is moved out of the 0U space
  • As future needs increase, just change the power strip no need for new controller and power meter.
]]>
4-20mAmp Converter https://enviromon.net/product/4-20mamp-converter/ Tue, 02 Jan 2024 06:32:54 +0000 https://enviromon.net/?post_type=product&p=1157 4-20mAmp Converter

Facilitating seamless integration, the 4-20mA converter is designed to link the sensorProbe with a 4-20mA sensor. Employing 4-20mA technology, this converter enables the transmission of analog signals over extended distances, effectively mitigating electrical interference challenges.

Operational efficiency is ensured with power drawn directly from the base unit. For comprehensive details, access datasheets and media resources by downloading the VC00 Datasheet.

]]>