Cabinet Temperature and Humidity Map Sensor

Cabinet Temperature and Humidity Map Sensor

$370.00

6x temperature sensor string and 2x humidity pre-wired for monitoring top, middle, bottom

Add to Quote

Description

Thermal Map Sensor

Monitor temperature differential between front and rear of your cabinet.

  • Temperature only
  • Dual Temperature and Humidity
  • Check for cabinet hotspots

Additional information

Option

, , ,

Advantages

Advantages Of Thermal Map Sensors

Obstructions within the cabinet

Cabling or other obstructions can impede the flow of air causing high-temperature differentials between the inlet and outlet temperatures. The cabinet analysis sensor with pressure differential can also help analyse airflow issues.

Server and cooling fan failures

As fans age, or fail, the airflow over the IT equipment will lessen. This leads to higher temperature differentials between front and rear.

Insufficient pressure differential to pull air through the cabinet

When there is an insufficient pressure differential between the front and rear of the cabinet, airflow will be less. The less cold air flowing through the cabinet, the higher the temperature differential front to rear will become.

Power Usage Effectiveness (PUE)

When the data is combined with the power consumption from the in-line power meter you can safely make adjustments in the data center cooling systems, without compromising your equipment, while instantly seeing the changes in your PUE numbers.

Rack Map Display

Rack Map Display

In the web user interface and AKCPro Server, thermal maps are displayed in a Rack Map view. This shows the temperature, and humidity at each point of the front and rear of the cabinet, together with animated arrows that show the front to rear temperature differential.

Multiple Cabinets

Monitor up to 16 cabinets from a single IP address. With a 16 sensor port SPX+, you consume only 1U of rack space, and save costs by having only one base unit. Thermal map sensors can be extended up to 15 meters from the SPX+.

Specification

Temperature
Never needs Calibration
Measurement Range  -40°C to +75°C / -40°F to +167°F
Measurement Resolution  0.1°C increments / 0.2°F increments
Measurement Accuracy  Maximum ±0.3 at -40ºC, minimum ±0.3 at +25ºC to +75ºC Maximum ±0.6 at -40ºF, minimum ±0.6 at +77ºF and to +167ºF
Communication Cable RJ45 jack to temperature sensor using UTP CAT5/6
Sensor Type semiconductor microprocessor controlled
Power Source powered by the sensorProbe+. No additional power needed.
Power Consumption Typical 75 mWatt, 15 mA
Number of sensors 6 temperature sensors
Humidity
Measurement range 0 to 100% Relative humidity
Resolution 1% for the sensorProbes and 0.1% for the securityProbe units.
Accuracy 25°C ±3%
Power Source powered by the sensorProbe. No additional power needed.
Power Consumption Typical 65 mWatt, 13 mA
Number of sensors 2 Humidity sensors
General
Maximum cable length 18 meters / 60 feet with approved low capacitance shielded UTP cable
Auto-sense sensorProbe+ unit auto detects the presence of the Thermal Map Sensor and configures the unit automaticaly.
Important Note Thermal Map Sensor is only compatible with the sensorProbe+ and securityProbe+ platforms.